Our Datacenter
Introduction
Ultima Hosts operates from one of the USA's premium datacenters which has provided over seven
years of high performance web hosting solutions. Currently, the datacenter has served
over 15,000 clients in 85 countries. The entire facility is staffed by highly trained,
industry experienced, and professionally educated technicians.
The datacenter has a central focus on redundancy allowing the network to rapidly
self-heal failures without interruptions to connectivity.
Ultima Hosts uses multi-tiered redundancy with a N+1 internal device elements
as well as entirely redundant chassis allowing any routing device to fail without
interrupting server data connectivity. All core routing and switching equipment
is state of the art Cisco.
The datacenter has exclusively selected premium Tier-1 bandwidth providers, ensuring
minimal latency and excellent reach ability on a global basis.
Providers include direct connectivity with MCI/UUnet, AT&T, and Savvis/Cable
& Wireless. The datacenter uses aggregate connectivity reaching 4,500+ networks
and just a single network away from the datacenter's uplinks.
SBC Diverse Path OC-48 Fiber
OC-48 Flashwave 4500 Fiber connectivity to the facility is supplied by an SBC OC-48
diverse path fiber optic sonet ring. Featuring level 7 path diversity the datacenter
uses sonet ring with multiple entry points into the facility as well as connectivity
directly to multiple carrier offices. There is no shared physical path at any point
in the entire sonet loop. This design allows for uninterrupted service even in the
event of a fiber cut, or other direct CO equipment failure. The datacenter's optical
equipment is capable of supporting multiple OC-192 connections.
Cisco GSR 12000 Border Routers
The datacenter's network connectivity begins at the border layer which connects
directly to the Tier 1 service providers as well as to the network core. The datacenter's
reliance on multiple devices each with internally redundant systems ensures the
highest levels of reliability.
Each Cisco GSR is capable of independently routing 60 gigabits of data at wire rate
while isolating any fault risk to each independent line card. Connections to the
core are derived independently enabling yet another layer of redundancy and performance
load balancing.
Cisco Sup720 Core
The datacenter's fully redundant network core handles bandwidth aggregation and
routing for the entire network. Each Cisco 6509 Sup720 is capable of routing up
to 400 million packets per second with a total capacity of 720 gigabits per second
each.
This layer is fully redundant with each unit possessing the ability to route the
entire core in the event of a device hardware or software failure. Core failure
recovery is a nearly instantaneous process and is fully automated by the self-healing
core elements.
Cisco 3550 Distribution Switches
Final layer3 distribution to rack switches as well as VLAN segmentation is handled
by Cisco Catalyst 3550 distribution switches. Each switch is capable of handling
simultaneous wire rate data traffic for every port configured ensuring optimal performance
and eliminating blocking potential to the core or individual rack switch.
At the rack layer the datacenter utilize Hewlett-Packard Procurve switches to follow
and further enforce VLAN segmentation protocols from the distribution layer as well
as offer final customer network access.
Datacenter Power Systems Overview
The datacenter's power systems feature extensive fault tolerance and resilience
at every layer. Incoming service is routed underground to a dedicated on-site transformer.
This system routes to the datacenter's transfer switch junction which also connects
to the datacenter's power generation facilities.
The datacenter's primary UPS is a 300kva Powerware 9315 featuring redundant battery
cabinets and a full maintenance bypass allowing for service and upgrades without
interruption of power to the datacenter's servers.
Liebert Precision power distribution units handle final power transformation and
distribution to racks.
Cummins Generator
Generator backup services are provided to the datacenter's facility by a Cummins
313kVa Diesel Generator featuring over 24 hrs of autonomous runtime before requiring
refueling.
Generator power is activated automatically in the event of a grid failure by the
transfer switch. The intermediate load is capable of being handled for over an hour
by the UPS, however this is not necessary as the generator is active and up to speed
within 16 seconds of a power failure.
Facility General Environment
The datacenter's facility includes over 11,000 square feet of available space. Construction
is built to surpass local building area codes and seismic requirements. Industry
standard hard floors are covered with vinyl tile and overhead wiring systems are
utilized for enhanced cooling and a more secure cable infrastructure.
Datacenter access is strictly limited to technical staff. Electronic security systems
control datacenter access and are accompanied by a full compliment of motion detecting
security cameras which are strategically placed throughout the entire facility.
Furthermore we use facility external walls are concrete powered to a height of twenty
feet.
Liebert 22 Ton AC Unit
Environmental processing systems include redundant Liebert Precision 22 ton up flow
air conditioning units. Temperature and humidity are precisely regulated year round
to ensure optimal equipment reliability. Each unit contains independent compressors
and cooling loops to further enhance fault tolerance and reliability.
Air filtration systems actively remove foreign particulates from circulation and
cycle the entire datacenter air supply in a matter of minutes.
The datacenter is a fully managed facility, as such technical staff includes level
3 technicians on site 24 hours per day, allowing incident response times to be
kept to a minimum and system integrity retained with utmost urgency.